203 research outputs found

    Aprotinin reduces cardiac troponin I release and inhibits apoptosis of polymorphonuclear cells during off-pump coronary artery bypass surgery

    Get PDF
    Objectives: In addition to blood-sparing effects, aprotinin may have cardioprotective and anti-inflammatory effects during cardiopulmonary bypass-assisted cardiac surgery. In this study, the authors examined whether aprotinin had cardioprotective and/or anti-inflammatory effects in patients undergoing off-pump coronary artery bypass grafting. Design: A prospective randomized clinical trial. Setting: University hospital. Participants: Fifty patients were randomized to control (n = 25) or aprotinin treatment (n = 25) groups. Interventions: Aprotinin was given as a loading dose (2 x 10(6) KIU) followed by a continuous infusion at 5 x 10(5) KIU/h until skin closure. Measurements and Main Results: Blood samples for cardiac troponin I; interleukin-6, interleukin-8, and interleukin-10; tumor necrosis factor a; and elastase were taken after anesthesia induction, completion of revascularization, and 6 hours, 12 hours, and 24 hours after revascularization. Blood samples were taken to assess for apoptosis in polymorphonuclear cells. Baseline plasma levels for cardiac troponin I did not differ between groups but were significantly lower in aprotinin-treated patients at the time of revascularization (P = 0.03) and 6 hours (p = 0.004) and 24 hours (p = 0.03) later. Aprotinin significantly reduced apoptosis in polymorphonuclear cells compared with control-treated patients (p = 0.04). There were no differences in plasma cytokine or elastase levels between groups. Conclusions: The authors conclude that aprotinin reduces perioperative cardiac troponin I release and attenuates apoptosis in polymorphonuclear cells but has no significant effects on plasma cytokine levels in patients undergoing off-pump coronary artery bypass graft surgery

    Initial clinical validation of a hybrid in silico—in vitro cardiorespiratory simulator for comprehensive testing of mechanical circulatory support systems

    Get PDF
    Simulators are expected to assume a prominent role in the process of design—development and testing of cardiovascular medical devices. For this purpose, simulators should capture the complexity of human cardiorespiratory physiology in a realistic way. High fidelity simulations of pathophysiology do not only allow to test the medical device itself, but also to advance practically relevant monitoring and control features while the device acts under realistic conditions. We propose a physiologically controlled cardiorespiratory simulator developed in a mixed in silico-in vitro simulation environment. As inherent to this approach, most of the physiological model complexity is implemented in silico while the in vitro system acts as an interface to connect a medical device. As case scenarios, severe heart failure was modeled, at rest and at exercise and as medical device a left ventricular assist device (LVAD) was connected to the simulator. As initial validation, the simulator output was compared against clinical data from chronic heart failure patients supported by an LVAD, that underwent different levels of exercise tests with concomitant increase in LVAD speed. Simulations were conducted reproducing the same protocol as applied in patients, in terms of exercise intensity and related LVAD speed titration. Results show that the simulator allows to capture the principal parameters of the main adaptative cardiovascular and respiratory processes within the human body occurring from rest to exercise. The simulated functional interaction with the LVAD is comparable to the one clinically observed concerning ventricular unloading, cardiac output, and pump flow. Overall, the proposed simulation system offers a high fidelity in silico-in vitro representation of the human cardiorespiratory pathophysiology. It can be used as a test bench to comprehensively analyze the performance of physically connected medical devices simulating clinically realistic, critical scenarios, thus aiding in the future the development of physiologically responding, patient-adjustable medical devices. Further validation studies will be conducted to assess the performance of the simulator in other pathophysiological conditions

    Causes and predictors of early mortality in patients treated with left ventricular assist device implantation in the European Registry of Mechanical Circulatory Support (EUROMACS)

    Get PDF
    Purpose: The aim of the study was to analyze early mortality after continuous-flow left ventricular assist device (LVAD) implantation which remains high. Methods: We analyzed consecutive (n = 2689) patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) undergoing continuous-flow LVAD implantation. The primary outcome was early (< 90 days) mortality. Secondary outcomes were differential causes of early post-operative death following LVAD implantation. Results: Univariable and multivariable analysis as well as regression analysis were used to examine determinants and differential causes of early (< 90 days) mortality after LVAD implantation. During the first 90 days, 2160 (80%) patients were alive with ongoing LVAD support, 40(2%) patients underwent heart transplantation, and 487(18%) deceased. The main causes of early death were MOF (36%), sepsis (28%), cardiopulmonary failure (CPF; 10%), CVA (9%), and right-sided heart failure (RHF, 8%). Furthermore, MOF and sepsis are 70% of causes of death in the first week. Independent clinical predictors of early death were age, female sex, INTERMACS profile 1 to 3, and ECMO. Laboratory predictors included elevated serum creatinine, total bilirubin, lactate, and low hemoglobin. Furthermore, hemodynamic predictors included elevated RA-to-PCWP ratio, pulmonary vascular resistance, and low systemic vascular resistance. Longer total implantation time was also independent predictor of early mortality. A simple model of 12 variables predicts early mortality following LVAD implantation with a good discriminative power with area under the curve of 0.75. Conclusions: In the EUROMACS registry, approximately one out of five patients die within 90 days after LVAD implantation. Early mortality is primarily dominated by multiorgan failure followed by sepsis. A simple model identifies important parameters which are associated with early mortality following LVAD implantation

    Management of Bleeding and Hemolysis During Percutaneous Microaxial Flow Pump Support A Practical Approach

    Get PDF
    © 2023 The Author(s). This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY), https://creativecommons.org/licenses/by/4.0/Percutaneous ventricular assist devices (pVADs) are increasingly being used because of improved experience and availability. The Impella (Abiomed), a percutaneous microaxial, continuous-flow, short-term ventricular assist device, requires meticulous postimplantation management to avoid the 2 most frequent complications, namely, bleeding and hemolysis. A standardized approach to the prevention, detection, and treatment of these complications is mandatory to improve outcomes. The risk for hemolysis is mostly influenced by pump instability, resulting from patient- or device-related factors. Upfront echocardiographic assessment, frequent monitoring, and prompt intervention are essential. The precarious hemostatic balance during pVAD support results from the combination of a procoagulant state, due to critical illness and contact pathway activation, together with a variety of factors aggravating bleeding risk. Preventive strategies and appropriate management, adapted to the impact of the bleeding, are crucial. This review offers a guide to physicians to tackle these device-related complications in this critically ill pVAD-supported patient population.Peer reviewe

    Paediatric aortic valve replacement using decellularized allografts

    Get PDF
    OBJECTIVES: Options for paediatric aortic valve replacement (AVR) are limited if valve repair is not feasible. Results of paediatric Ross procedures are inferior to adult Ross results, and mechanical AVR imposes constant anticoagulation with the inherent risks.METHODS: The study design was a prospective, multicentre follow-up of all paediatric patients receiving decellularized aortic homografts (DAHs) for AVR in 8 European centres.RESULTS: A total of 106 children (77 boys) were operated (mean age 10.1 +/- 4.8 years, DAH diameter 20.5 +/- 3.8 mm). A total of 60 (57%) had undergone previous surgical interventions: 34 with 1, 15 with 2 and 11 with >3. There was one early death in a 12-year-old girl, who underwent her fourth aortic valve operation, due to intracerebral haemorrhage on extracorporeal membrane oxygenation after coronary reimplantation problems following 3-sinus reconstruction 1 year earlier. One 2-year-old patient died due to sepsis 2 months postoperatively with no evidence for endocarditis. In addition, a single pacemaker implantation was necessary and a 2.5-year-old girl underwent successful HTx due to chronic myocardial failure despite an intact DAH. After a mean follow-up of 3.30 +/- 2.45 years, primary efficacy end points mean peak gradient (18.1 +/- 20.9 mmHg) and regurgitation (mean 0.61 +/- 0.63, grade 0-3) were very good. Freedom from death/explantation/endocarditis/bleeding/stroke at 5 years was 97.8 +/- 1.6/85.0 +/- 7.4/100/100/100% respectively. Calculated expected adverse events were lower for DAH compared to cryopreserved homograft patients (mean age 8.9 years), lower than in Ross patients (9.4 years) and in the same range as mechanical AVR (12.8 years).CONCLUSIONS: Even though the overall number of paediatric DAH patients and the follow-up time span are still limited, our data suggest that DAHs may present a promising additional option for paediatric AVR.Thoracic Surger

    Repeated successful surgical rescues of early and delayed multiple ruptures of ventricular septum, right ventricle and aneurysmal left ventricle following massive biventricular infarction

    Get PDF
    A 58 year old man underwent 6 surgical interventions for various complications of massive biventricular myocardial infarction over a period of 2 years following acute occlusion of a possibly "hyperdominant" left anterior descending coronary artery. These included concomitant repair of apicoanterior post-infarction VSD and right ventricular free wall rupture, repeat repair of recurrent VSD following inferoposterior extension of VSD in the infarcted septum 5 weeks later, repair of delayed right ventricular free wall rupture 4 weeks subsequently, repair of a bleeding left ventricular aneurysm eroding through left chest wall 16 months thereafter, repair of right upper lobe lung tear causing massive anterior mediastinal haemorrhage, mimicking yet another cardiac rupture, 2 months later, followed, at the same admission, 2 weeks later, by sternal reconstruction for dehisced and infected sternum using pedicled myocutaneous latissimus dorsi flap. 5 years after the latissimus myoplasty, the patient remains in NYHA class 1 and is leading a normal life

    Introduction: Rethinking democratization and election observation

    Get PDF
    This book brings together studies on the broad theme of elections and democratization in Africa since roughly 1989. It is based on a seminar held in The Netherlands in February 1997, and includes chapters on both electoral processes, especially the role of foreign observers therein, and the historical and sociocultural backgrounds or contexts of democratization, elections and political legitimacy. Part 1 deals with elections and election observation in Africa in general (contributions by O. van Cranenburgh, S. Ellis, I. van Kessel, B. de Gaay Fortman). Part 2 consists of country studies (M. Doornbos on Uganda, D. Foeken en T. Dietz on Kenya, J. Abbink on Ethiopia, R. van Dijk on Malawi, R. Buijtenhuijs on Chad, and M.-F. Lange on Mali). Part 3 includes a chapter that reflects the discussions held at the seminar between observers, academics and policymakers in the Netherlands Ministry of Foreign Affairs (W. van Binsbergen en J. Abbink); a review of Dutch policies on election observation in Africa during the period 1992-1997 (O. van Cranenburgh); and a discussion of the 1997 general elections in Kenya, where a new approach of election observation was introduced (M. Rutten)ASC – Publicaties niet-programma gebonde
    • …
    corecore